MATERIAL SAFETY DATA SHEET
Emergency Telephone: 800-526-4371
Section 1: Chemical Product and Company Information
Identity:
TDC10 Black Toner Cartridge
MSDS No.
CP- 282
Product ID:
117-0191
Issued: 06/15/2004
Synonyms
& Common
Names:
Uses:
Chemical
Formula:
TDC-10 Toner Developer Cartridge
Black Toner for
Lanier 6610
Lanier 6610 Copier
Mixture
Supersedes:
Date:
Prepared by:
Approved by:
European
Contact:
05/08/1995
06/15/2004
EH&S Department 770-496-9500
Larry Choskey, Manager, CEH&S
Walter Fricke, Manager, Safety &
Environment,
Lanier Worldwide, Inc.
Im Taubental D-41468 Neuss,
Germany +49-2131-387-177
Section 2: Composition / Information on Ingredients
Toner Component
Percent
CAS No.
Exposure Limits
Source
Styrene acrylate copolymer 92 25767-47-9 Not listed
n/a
Carbon black 4 1333-86-4 3.5mg/m
3
3.5mg/m
3
OSHA PEL
ACGIH TWA
Organic pigment 4 8005-02-5 Not listed N/a
Developer Component
Iron powder 93.5 7439-89-6 Not listed N/a
Carbon black 0.3 1333-86-4
3.5mg/m
3
3.5mg/m
3
OSHA PEL
ACGIH TWA
Difluorethylene polymer 0.5 24937-79-9 Not listed N/a
Styrene acrylate copolymer 5.5 25767-47-9 Not listed n/a
Organic pigment 0.2 8005-02-5 Not listed N/a
*PEL as the product: 15mg/m
3
(total dust), 5mg/m
3
(respirable dust)
*TLV as the product: 10mg/m
3
(total dust), 5mg/m
3
(respirable dust)
Section 3: Hazards Identification
HMIS Rating:
FLAMMABILITY = 1 HEALTH = 1
REACTIVITY = 0 SPECIAL = none
Health Hazards (Acute, Chronic, Immediate and Potential): Minimum irritation to respiratory tract may occur as with exposure
to any non-toxic dust. May cause gasping if inhaled. Inhalation should be avoided. May cause temporary eye discomfort.
Health Hazards of Long Term exposure (Chronic): Prolonged inhalation of excessive dust may cause lung damage. It is
attributed to “lung overloading”, a generic response to excessive amounts of any dust retained in the lungs for a prolonged interval.
Use of this product, as intended, does not result in inhalation of excessive dust.
Carcinogenicity: Carbon Black was reclassified as a Group 2B by the IARC in 1996 based upon the result of only the inhalation
study in rats. However, there was not observed the incidence of tumors on the test results on dermal or oral studies. Also, 2-years
inhalation study using a typical toner containing carbon black showed no association between toner exposure and animal tumors.
Section 4: First Aid Measures
Inhalation:
Gargle with water. Remove to fresh air if effects
occur. Get medical attention if needed.
Eye Contact:
In case of contact, immediately flush eyes
with water for 15 minutes. Get medical
attention if needed.
Skin Contact:
Wash with soap and water.
Ingestion:
Dilute stomach contents with several
glasses of water. Get medical attention.
Section 5: Fire Fighting Measures
Suitable extinguishing media: CO
2
, dry chemical, foam or water.
Extinguishing media which may not be used for safety
reasons: none
Special protective equipment for fire fighters: none
UEL: n/a LEL: n/a
your document management partner
Page view 0
1 2 3

Summary of Contents

Page 1 - MATERIAL SAFETY DATA SHEET