Lanier 4800015 Datasheet

Browse online or download Datasheet for Toners & Laser Cartridges Lanier 4800015. Lanier 4800015 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Lanier Worldwide, Inc.
2300 Parklake Dr., N. E.
Atlanta, GA 30345-2979
Emergency Telephone: (800) 526-4371
MATERIAL SAFETY DATA SHEET
Section 1: Chemical Product and Company Information
Identity:
Toner for 5025
MSDS No.
CP- 306C
Product ID: 480-0015 Issued: 9/29/99
Synonyms
& Common
Names:
Uses:
Chemical
Formula:
Toner for
Lanier 5025
Lanier 5025
Mixture
Supersedes:
Date:
Prepared by:
Approved by:
European Contact:
None
9/29/99
Lanier QA/EH&S Department 770-493-2361
Larry Choskey, Sr. Quality Assurance Engineer
Lanier Worldwide, WSM Europe,
Walter Fricke,
Im Taubental D-41468 Neuss, Germany
+49-2131-387-177
Section 2: Composition / Information on Ingredients
PERCENT CAS No. EXPOSURE LIMITS SOURCE
Polyester resin 68.0 Confidential Not listed n/a
Styrene acrylic polymer 17.0 26655-10-7 Not listed n/a
Carbon black 8.0 1333-86-4 3.5mg/m
3
3.5mg/m
3
OSHA PEL ACGIH
TWA
Wax 4.0 8015-86-9 Not listed
N/a
Dye 2.0 31714-55-3 Not listed n/a
Silica 1.0 172640-49-2 Not listed N/a
*PEL as the product: 15mg/m
3
(total dust), 5mg/m
3
(respirable dust)
*TLV as the product: 10mg/m
3
(total dust), 5mg/m
3
(respirable dust)
Section 3: Hazards Identification
HMIS Rating:
FLAMMABILITY = 1 HEALTH = 1
REACTIVITY = 0 SPECIAL = none
Health Hazards (Acute, Chronic, Immediate and Potential): Minimum irritation to respiratory tract may occur as with exposure to any non-toxic dust.
May cause gasping if inhaled. Inhalation should be avoided. May cause temporary eye discomfort.
Health Hazards of Long Term exposure (Chronic): A manufacturer sponsored chronic inhalation study in rats using a special test toner revealed
there were no lung changes at all in the lowest exposure level (1mg/m
3
), the most relevant level to potential human exposures. A very slight degree of
fibrosis was noted in 25% of the animals at the middle exposure level (4mg/m
3
), while a slight degree of fibrosis was observed at the highest exposure
level (16mg/m
3
) in all animals. These findings are attributed to “Lung Overloading”, a generic response to excessive amount of any dust retained in the
lungs for a prolonged interval. The special test toner was ten times more respirable than commercially available toner to comply with EPA testing
protocol and would not function properly in Xerographic equipment.
Carbon Black is listed on the IARC Monograph and the Massachusetts Substance List. The IARC has evaluated the evidence for the carcinogenicity of
Carbon Black as inadequate to determine a carcinogenic risk for humans.
This product contains no known hazardous materials as defined by the OSHA Hazard Communication Standard 29 CFR 1910.1200.
Section 4: First Aid Measures
Inhalation:
Remove to fresh air if effects occur. Get medical
attention if needed. Eye Contact:
In case of contact, immediately flush eyes with
water for 5 minutes. Get medical attention if
needed.
Skin Contact: Wash with soap and water. Ingestion: Dilute stomach contents with several glasses of
water. Get medical attention.
Section 5: Fire Fighting Measures
Suitable extinguishing media: CO
2
, dry chemical, foam or water.
Extinguishing media which may not be used for safety reasons: none
This material will burn in case of fire. The decomposition products are CO, CO
2
, and No
x
. Avoid inhalation of smoke.
Special protective equipment for fire fighters: none
UEL: n/a LEL: n/a
Section 6: Accidental Release Measures
Spill / leak Procedures: If spilled, sweep up using an approved toner vacuum with a 0.5 micron filter or smaller, such as the Atrix AAA Toner Vacuum or
3M Toner Vacuum. Use of a vacuum cleaner not rated for toner particles, could result in a fire or personal injury. Remove residue with soap and cold
water.
Miscellaneous: Keep product out of sewers and watercourses.
Page view 0
1 2

Summary of Contents

Page 1 - MATERIAL SAFETY DATA SHEET

Lanier Worldwide, Inc.2300 Parklake Dr., N. E.Atlanta, GA 30345-2979Emergency Telephone: (800) 526-4371MATERIAL SAFETY DATA SHEETSection 1: Chemical

Page 2

MATERIAL SAFETY DATA SHEETPage 2 of CP-306CInformation on this data sheet represents our current data and best opinion as to t

Comments to this Manuals

No comments