Lanier 5485 User Manual

Browse online or download User Manual for Toners & Laser Cartridges Lanier 5485. Lanier 5485 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 3
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Lanier Worldwide, Inc.
2300 Parklake Dr., N. E.
Atlanta, GA 30345-2979
Emergency Telephone: (800) 526-4371
MATERIAL SAFETY DATA SHEET
Section 1: Chemical Product and Company Information
Identity:
5485 Toner
MSDS No.
CP- 339
Product ID: 480-0034 Issued: 04/20/2000
Synonyms
& Common
Names:
Uses:
Chemical
Formula:
Toner for Lanier 5485
Lanier 5485
Mixture
Supersedes:
Date:
Prepared by:
Approved by:
European
Contact:
None
04/20/2000
EH&S Department 770-496-9500
Larry Choskey, Manager, CEH&S
Walter Fricke, Manager, Safety &
Environment,
Lanier Worldwide, Inc.
Im Taubental D-41468 Neuss,
Germany +49-2131-387-177
Section 2: Composition / Information on Ingredients
PERCENT CAS No. EXPOSURE LIMITS SOURCE
Polyester resin 60 80 Confidential 8mg/m
3
ACGIH TWA
Styrene acrylic polymer 10 30 25767-47-9 Not listed N/a
Carbon black 7 15 1333-86-4 3.5mg/m
3
3.5mg/m
3
OSHA PEL ACGIH TWA
Wax < 5 8015-86-9 Not listed
N/a
Dye < 1 31714-55-3 Not listed
N/a
*PEL as the product: 15mg/m
3
(total dust), 5mg/m
3
(respirable dust)
*TLV as the product: 10mg/m
3
(total dust), 5mg/m
3
(respirable dust)
Section 3: Hazards Identification
HMIS Rating:
FLAMMABILITY = 1 HEALTH = 1
REACTIVITY = 0 SPECIAL = none
Health Hazards (Acute, Chronic, Immediate and Potential): Minimum irritation to respiratory tract may occur as with exposure to any non-
toxic dust. May cause gasping if inhaled. Inhalation should be avoided. May cause temporary eye discomfort.
Health Hazards of Long Term exposure (Chronic): A manufacturer sponsored chronic inhalation study in rats using a special test toner
revealed there were no lung changes at all in the lowest exposure level (1mg/m
3
), the most relevant level to potential human exposures. A very
slight degree of fibrosis was noted in 25% of the animals at the middle exposure level (4mg/m
3
), while a slight degree of fibrosis was observed
at the highest exposure level (16mg/m
3
) in all animals. These findings are attributed to “Lung Overloading”, a generic response to excessive
amount of any dust retained in the lungs for a prolonged interval. The special test toner was ten times more respirable than commercially
available toner to comply with EPA testing protocol and would not function properly in Xerographic equipment.
Carbon Black is listed on the IARC Monograph and the Massachusetts Substance List. The IARC has evaluated the evidence for the
carcinogenicity of Carbon Black as inadequate to determine a carcinogenic risk for humans.
This product contains no known hazardous materials as defined by the OSHA Hazard Communication Standard 29 CFR 1910.1200.
Section 4: First Aid Measures
Inhalation:
Remove to fresh air if effects occur. Get medical
attention if needed.
Eye Contact:
In case of contact, immediately flush eyes with
water for 15 minutes. Get medical attention if
needed.
Skin Contact: Wash with soap and water. Ingestion:
Dilute stomach contents with several glasses
of water. Get medical attention.
Section 5: Fire Fighting Measures
Suitable extinguishing media: CO
2
, dry chemical, foam or water.
Extinguishing media which may not be used for safety reasons: none
This material will burn in case of fire. The decomposition products are CO, CO
2
, and No
x
. Avoid inhalation of smoke.
Special protective equipment for fire fighters: none
UEL: n/a LEL: n/a
Page view 0
1 2 3

Summary of Contents

Page 1 - MATERIAL SAFETY DATA SHEET

Lanier Worldwide, Inc. 2300 Parklake Dr., N. E. Atlanta, GA 30345-2979 Emergency Telephone: (800) 526-4371 MATERIAL SAFETY DATA SHEET Section 1

Page 2

MATERIAL SAFETY DATA SHEET Page 2 of CP-339 Information on this data sheet represents our current data and best opinion as to

Page 3

MATERIAL SAFETY DATA SHEET Page 3 of CP-339 Information on this data sheet represents our current data and best opinion as to

Comments to this Manuals

No comments